Yichao YangandGitHub 9dda852c00 Handle system time move backward case in timer task processing (#7030)
## What changed?
<!-- Describe what has changed in this PR -->
- Handle system time move backward case in timer task processing by
using max(now(), task visibility timestamp)

## Why?
<!-- Tell your future self why have you made these changes -->
- Monotonic time is used in time.Time comparison only when both operands
have monotonic time value. In our case, the timestamp stored/derived
in/from mutable state doesn't have monotonic, thus the comparison logic
will use wall clock time to decide if a timer task should be processed.
If wall clock move backwards (after we verifies that now() > task
visibility timestamp when submitting the task to the task scheduler),
the timer task will be dropped and cause workflow to stuck.

## How did you test it?
<!-- How have you verified this change? Tested locally? Added a unit
test? Checked in staging env? -->
- Unit tests

## Potential risks
<!-- Assuming the worst case, what can be broken when deploying this
change to production? -->
- In worst case, we will execute a timer task logic earlier than
expected.

## Documentation
<!-- Have you made sure this change doesn't falsify anything currently
stated in `docs/`? If significant
new behavior is added, have you described that in `docs/`? -->

## Is hotfix candidate?
<!-- Is this PR a hotfix candidate or does it require a notification to
be sent to the broader community? (Yes/No) -->
- Could be. But the bug should be very rare as the use millisecond
precision when doing time comparison in timer task processing.
2025-01-16 09:41:35 -08:00
..
2024-11-22 10:53:49 -08:00
2024-11-22 10:53:49 -08:00
2024-08-23 14:48:10 -06:00