The start-up report warned about every CPU lane on every start: cevm's Go entry passes no host, so a CPU lane declines the health battery, and a build with no library linked runs nothing at all. Those lanes are what they are, not something that went wrong, so they are named together in one info line; a GPU lane that does not run the battery is still a warning of its own. A loaded library of another ABI is one warning, and no lane is probed. The report tests move out of backend_cgo_test.go, which the native build failed: it expected ErrNotLinked from a build that links the library. cevmreport_test.go runs in every build and holds the start-up report to warn only about a GPU lane. Co-authored-by: Hanzo Dev <[email protected]>
76 lines
2.6 KiB
Go
76 lines
2.6 KiB
Go
// What this binary can execute with: the C++ library's ABI, the backends it
|
|
// offers, and what each answered to the health battery.
|
|
//
|
|
// There is nothing to select. Choosing an EVM is choosing which plugin binary
|
|
// the host runs, not a switch inside the Go EVM, so this only says what came
|
|
// up. The cevm package carries its own build tags, so one file serves every
|
|
// build: without the native library linked it reports the one backend it has.
|
|
package main
|
|
|
|
import (
|
|
"errors"
|
|
|
|
"github.com/luxfi/chains/evm/cevm"
|
|
"github.com/luxfi/log"
|
|
)
|
|
|
|
func reportCevm(logger log.Logger) {
|
|
abi := cevm.LibraryABIVersion()
|
|
logger.Info("cevm linked", "abi", abi, "backends", cevm.AvailableBackends())
|
|
if abi != cevm.ABIVersion {
|
|
// Every block is declined, so no lane has anything to report.
|
|
logger.Warn("cevm library speaks another ABI; the Go EVM runs every block",
|
|
"library", abi, "reads", cevm.ABIVersion)
|
|
return
|
|
}
|
|
reportHealth(logger, cevm.Health())
|
|
}
|
|
|
|
// reportHealth says what the backends answered to the health battery.
|
|
//
|
|
// A lane that runs no block in any build of this kind is said once, at info:
|
|
// a CPU lane, which cevm's Go entry passes no host and so runs nothing on,
|
|
// and the one lane of a build with no library. That is what the lane is, not
|
|
// something that went wrong, and a warning every start would bury the ones
|
|
// that did. Every other lane is reported on its own.
|
|
func reportHealth(logger log.Logger, reports []cevm.HealthReport) {
|
|
var idle []string
|
|
for _, h := range reports {
|
|
if runsNothing(h) {
|
|
idle = append(idle, h.Name)
|
|
continue
|
|
}
|
|
report(logger, h)
|
|
}
|
|
if len(idle) > 0 {
|
|
logger.Info("cevm runs no block on these backends; the Go EVM does", "backends", idle)
|
|
}
|
|
}
|
|
|
|
// runsNothing reports whether h is a lane that runs no block by what it is: a
|
|
// CPU lane that declined, or a lane with no library behind it.
|
|
func runsNothing(h cevm.HealthReport) bool {
|
|
if h.OK {
|
|
return false
|
|
}
|
|
if errors.Is(h.Err, cevm.ErrNotLinked) {
|
|
return true
|
|
}
|
|
cpu := h.Backend == cevm.CPUSequential || h.Backend == cevm.CPUParallel
|
|
return cpu && errors.Is(h.Err, cevm.ErrDeclined)
|
|
}
|
|
|
|
// report says what one cevm backend answered to the health battery: at info
|
|
// when it ran it, and at warn, with the probe and the reason, when it did not.
|
|
// A GPU lane that declines the battery's funded transfer has no device, or a
|
|
// device that does not work, and the Go EVM is running every block it would.
|
|
func report(logger log.Logger, h cevm.HealthReport) {
|
|
if h.OK {
|
|
logger.Info("cevm backend healthy",
|
|
"backend", h.Name, "probes", h.ProbesRun, "gas", h.GasUsed)
|
|
return
|
|
}
|
|
logger.Warn("cevm backend not healthy",
|
|
"backend", h.Name, "probe", h.Probe, "err", h.Err)
|
|
}
|